Legend
Legend
PROGRAM LEGEND
Legend
VERSION 80-1
(SEPTEMBER 1980) Legend
VERSION 84-1
(NOVEMBER 1984) Legend
VERSION 86-1 (JANUARY
1986) *CORRECTED BASED ON USER COMMENTS
Legend
*FORTRAN-77/H VERSION Legend
VERSION 87-1 (JANUARY
1987) *CORRECTED BASED ON USER COMMENTS
Legend
VERSION 88-1 (JULY
1988) *OPTION...INTERNALLY DEFINE ALL
I/O Legend
FILE NAMES (SEE, SUBROUTINE
FILEIO Legend
FOR DETAILS).
Legend
*IMPROVED BASED ON USER COMMENTS.
Legend
VERSION 89-1 (JANUARY
1989) *PSYCHOANALYZED BY PROGRAM FREUD TO
Legend
INSURE PROGRAM WILL NOT DO ANYTHING
Legend
CRAZY.
Legend
*UPDATED TO USE NEW PROGRAM CONVERT
Legend
KEYWORDS.
Legend
*ADDED LIVERMORE CIVIC COMPILER
Legend
CONVENTIONS. Legend
VERSION 92-1 (JANUARY
1992) *FOR ANGULAR DISTRIBUTIONS CALCULATED
Legend
FROM LEGENDRE COEFFICIENTS, INTERVAL
Legend
HALF TO CONVERGENCE.
Legend
*UPDATED BASED ON USER COMMENTS
Legend
*ADDED FORTRAN SAVE OPTION
Legend
*ADDED SELECTED OF DATA TO PROCESS
Legend
BY MAT/MF/MT/ENERGY RANGES.
Legend
*WARNING...THE INPUT PARAMETER FORMAT
Legend
HAS BEEN CHANGED - FOR DETAILS SEE
Legend
BELOW. Legend
VERSION 92-2 (SEPT.
1992) *CORRECTED PROCESSING OF
ISOTROPIC Legend
ANGULAR DISTRIBUTIONS
Legend
VERSION 94-1 (JANUARY
1994) *VARIABLE ENDF/B DATA FILENAMES
Legend
TO ALLOW ACCESS TO FILE STRUCTURES
Legend
(WARNING - INPUT PARAMETER FORMAT
Legend
HAS BEEN CHANGED) Legend
*CLOSE ALL FILES BEFORE TERMINATING
Legend
(SEE, SUBROUTINE ENDIT)
Legend
VERSION 96-1 (JANUARY
1996) *COMPLETE RE-WRITE
Legend
*IMPROVED COMPUTER INDEPENDENCE
Legend
*ALL DOUBLE PRECISION
Legend
*ON SCREEN OUTPUT
Legend
*UNIFORM TREATMENT OF ENDF/B I/O
Legend
*IMPROVED OUTPUT PRECISION
Legend
*INCREASED MAX. POINTS FROM 5,000
Legend
TO 20,000.
Legend
VERSION 99-1 (MARCH
1999) *CORRECTED CHARACTER TO
FLOATING Legend
POINT READ FOR MORE DIGITS Legend
*UPDATED TEST FOR ENDF/B FORMAT
Legend
VERSION BASED ON RECENT FORMAT CHANGE Legend
*GENERAL IMPROVEMENTS BASED ON
Legend
USER FEEDBACK
Legend
VERS. 2000-1
(FEBRUARY 2000)*GENERAL IMPROVEMENTS BASED ON Legend
USER FEEDBACK
Legend
VERS. 2002-1 (MAY
2002) *OPTIONAL INPUT
PARAMETERS Legend
Legend
OWNED, MAINTAINED AND
DISTRIBUTED BY
Legend
------------------------------------ Legend
THE NUCLEAR DATA
SECTION Legend
INTERNATIONAL ATOMIC
ENERGY AGENCY
Legend
P.O. BOX 100 Legend
A-1400, VIENNA,
AUSTRIA Legend
EUROPE
Legend
Legend
ORIGINALLY WRITTEN
BY
Legend
------------------------------------ Legend
DERMOTT E.
CULLEN Legend
UNIVERSITY OF
CALIFORNIA Legend
LAWRENCE LIVERMORE
NATIONAL LABORATORY
Legend
L-159 Legend
P.O. BOX 808 Legend
LIVERMORE, CA
94550 Legend
U.S.A.
Legend
TELEPHONE 925-423-7359 Legend
E. MAIL CULLEN1@LLNL.GOV Legend
WEBSITE HTTP://WWW.LLNL.GOV/CULLEN1 Legend
Legend
PURPOSE
Legend
-------
Legend
CALCULATE LINEARLY INTERPOLABLE TABULATED
ANGULAR DISTRIBUTIONS Legend
STARTING FROM DATA IN
THE ENDF/B FORMAT. ANGULAR DISTRIBUTIONS
Legend
MAY BE DESCRIBED IN
THE ENDF/B FORMAT IN ONE OF THREE WAYS.
Legend
FOR EACH OF THESE
THREE FORMS THE USER MAY CHOOSE (SEE, INPUT Legend
OPTIONS) TO EITHER
COPY EACH TYPE OF DATA OR TO PROCESS IT AT
Legend
AS FOLLOWS, Legend
Legend
(1) ANGULAR
DISTRIBUTION IS ISOTROPIC AT ALL ENERGIES (LTT=0) Legend
------------------------------------------------------------- Legend
IN THIS CASE THE
INPUT DATA DOES NOT INCLUDE ANY ANGULAR Legend
DISTRIBUTIONS. A
SECTION MERELY CONTAINS A FLAG TO INDICATE Legend
THE ANGULAR
DISTRIBUTION IS ISOTROPIC AT ALL ENERGIES. IN THIS Legend
CASE THE SECTION IS
OUTPUT IN EXACTLY THE SAME FORM IN WHICH IT
Legend
WAS READ FROM THE
INPUT. Legend
Legend
(2) ANGULAR
DISTRIBUTIONS GIVEN BY LEGENDRE COEFFICIENTS (LTT=1) Legend
---------------------------------------------------------------- Legend
LEGENDRE COEFFICIENTS
ARE GIVEN AT A SERIES OF ENERGIES. AN
Legend
INTERPOLATION LAW IS
GIVEN BETWEEN ENERGIES. THE INTERPOLATION
Legend
LAW BETWEEN ENERGIES
IS COPIED AS INPUT (I.E., NO ATTEMPT IS
Legend
MADE TO LINEARIZE THE
VARIATION WITH ENERGY). FOR EACH ENERGY AT
Legend
WHICH LEGENDRE
COEFFICIENTS ARE GIVEN A LINEARLY INTERPOLABLE Legend
ANGULAR DISITRIBUTION
IS RECONSTRUCTED IN THE SYSTEM IN WHICH THE
Legend
THE COEFFICIENTS ARE
GIVEN (I.E., CM OR LAB - NO ATTEMPT IS MADE
Legend
TO CONVERT FROM ONE
SYSTEM TO THE OTHER). A MAXIMUM OF 30 LEGENDRE Legend
COEFFICIENTS IS ALLOWED. REGARDLESS OF THE
NUMBER OF COEFFICIENTS Legend
INPUT THE PROGRAM
WILL ONLY USE COEFFICIENTS UP TO THE LAST ORDER Legend
AT WHICH THE
COEFFICIENTS ARE NON-ZERO (E.G. IF COEFFICIENTS P1 Legend
THROUGH P12 ARE READ,
BUT P9=P10=P11=P12=0.0, THE PROGRAM WILL
Legend
ONLY USE COEFFICIENTS
UP TO P8). IF OVER 30 NON-ZERO COEFFICIENTS
Legend
ARE READ ONLY THE
FIRST 30 WILL BE USED. Legend
Legend
(2) ANGULAR
DISTRIBUTIONS IS TABULATED (LTT=2) Legend
---------------------------------------------------------------- Legend
ANGULAR DISTRIBUTIONS
ARE GIVEN AT A SERIES OF ENERGIES. AN
Legend
INTERPOLATION LAW IS
GIVEN BETWEEN ENERGIES AND A SECOND
Legend
INTERPOLATION LAW IS
GIVEN AT EACH ENERGY TO INTERPOLATE BETWEEN
Legend
THE POINTS IN EACH
TABULATED DISTRIBUTION. AT EACH ENERGY THE
Legend
ANGULAR DISTRIBUTION
WILL BE CONVERTED TO LINEARLY INTERPOLABLE
Legend
FORM. THE
INTERPOLATION BETWEEN ENERGIES IS OUTPUT EXACTLY AS Legend
INPUT. THE
INTERPOLATION LAW AT EACH ENERGY IS OUTPUT TO INDICATE Legend
THE NOW LINEARLY
INTERPOLABLE ANGULAR DISTRIBUTION. Legend
Legend
POINT VALUES -
NORMALIZED VS. UNNORMALIZED
Legend
------------------------------------------------------------------
Legend
THE VALUE OF AN
ANGULAR DISTRIBUTION AT ANY COSINE WILL BE Legend
CORRECTLY CALCULATED
BY THIS CODE, BASED EITHER DIRECTLY ON THE
Legend
ANGULAR DISTRIBUTION,
OR ON THE SUM OF THE CONTRIBUTING LEGENDRE
Legend
MOMENTS.
Legend
Legend
ENDF/B ANGULAR
DISTRIBUTIONS ARE BY DEFINITION NORMALIZED WHEN Legend
INTEGRATED OVER
COSINE. THEREFORE THIS CODE WILL NORMALIZE EACH Legend
ANGULAR DISTRIBUTION
BEFORE IT IS OUTPUT. THE OUTPUT REPORT FROM
Legend
THIS CODE WILL
INDICATE THE NORMALIZATION FACTOR USED. Legend
Legend
THE REASON THAT AN
ANGULAR DISTRIBUTION MAY NOT BE NORMALIZED IS
Legend
DUE TO THE APPROXIMATION
OF CREATING LINEARLY INTERPOLABLE
Legend
TABULATED ANGULAR
DISTRIBUTIONS - THE MORE ACCURATELY THIS IS Legend
DONE THE CLOSER THE
NORMALIZATION FACTOR WILL BE TO UNITY. AS YOU
Legend
DECREASE THE
ALLOWABLE ERROR THE NORMALIZED VALUES WILL APPROACH Legend
THE CORRECT POINT
VALUES CALCULATED BY THE CODE. Legend
Legend
SINCE THE DATA IS
NORMALIZED PRIOR TO OUTPUT THE RESULTS IN THE Legend
ENDF/B FORMAT MAY
DIFFER SLIGHTLY FROM VALUES REFERRED TO BE ERROR Legend
MESSAGES, ETC.
PRINTED BY THE CODE DURING EXECUTION. IN ALL CASES Legend
THE VALUES PRINTED BY
THE CODE IN ERROR MESSAGES, ETC. SHOULD BE
Legend
CONSIDERED TO BE THE
CORRECT VALUES AND THE OUTPUT TABULATED
Legend
ANGULAR DISTRIBUTIONS
APPROXIMATE DUE TO THE RE-NORMALIZATION -
Legend
TO RE-ITERATE, THE
OUTPUT TABULATED VALUES ARE APPROXIMATE DUE
Legend
TO THE APPROXIMATIONS
USED IN CONSTRUCTING LINEAR INTERPOLABLE
Legend
ANGULAR DISTRIBUTIONS
TO WITHIN SOME ALLOWABLE TOLERANCE.
Legend
Legend
ELIMINATION OF
NEGATIVE VALUES Legend
------------------------------ Legend
THE RECONSTRUCTED
ANGULAR DISTRIBUTION WILL BE TESTED AND IF IT Legend
IS NEGATIVE AT ONE OR
MORE COSINES AN ERROR MESSAGE WILL BE OUTPUT Legend
AND BASED ON THE
INPUT OPTION SELECTED ONE OF THE FOLLOWING Legend
CORRECTIVE ACTIONS
WILL BE TAKEN (SEE, INPUT OPTIONS),
Legend
(1) NO
CORRECTION Legend
(2) CHANGE INDIVIDUAL
LEGENDRE COEFFICIENTS (EACH BY LESS THAN
Legend
1.0 PER-CENT)
UNTIL THE RECONSTRUCTED ANGULAR DISTRIBUTION Legend
IS POSITIVE
(MINIMUM MORE THAN 1 MILLI-BARN). THE ALLOWABLE Legend
PER-CENT CHANGE
IN COEFFICIENTS AND MINIMUM CROSS SECTION CAN
Legend
BE CHANGED BY
INPUT. Legend
(3) CHANGE ALL
LEGENDRE COEFFICIENTS TO FORCE DISTRIBUTION TO BE Legend
POSITIVE (MINIMUM
MORE THAN 1 MILLI-BARN). WITH THIS OPTION
Legend
THERE IS NO
RESTRICTION ON THE AMOUNT THAT EACH COEFFICIENT Legend
IS CHANGED AND AS
SUCH THIS OPTION SHOULD BE USED WITH
Legend
CAUTION AND ONLY
AS A LAST RESORT IF NO OTHER APPROACH CAN
Legend
BE USED TO MAKE
THE DISTRIBUTION POSITIVE.
Legend
Legend
OUTPUT
Legend
------
Legend
THE USER MAY REQUEST
OUTPUT OF EITHER, Legend
(1) TABULATED VALUES
- POSSIBLY CORRECTED TO ELIMINATE NEGATIVE
Legend
VALUES. THE
TABULATED DISTRIBUTION WILL BE NORMALIZED BEFORE Legend
OUTPUT.
Legend
(2) LEGENDRE
COEFFICIENTS - POSSIBLY CORRECTED TO ELIMINATE Legend
NEGATIVE VALUES
AND WITHOUT HIGHER ORDER ZERO COEFFICIENTS.
Legend
BY DEFINITION
DISTRIBUTIONS DEFINED BY LEGENDRE COEFFICIENTS Legend
ARE NORMALIZED TO
UNITY.
Legend
Legend
(3) ANGULAR
DISTRIBUTIONS GIVEN BY A TABULATION (LTT=2) Legend
------------------------------------------------------- Legend
TABULATED ANGULAR
DISTRIBUTIONS ARE GIVEN AT A SERIES OF ENERGIES. Legend
AN INTERPOLATION LAW
IS GIVEN BETWEEN ENERGIES. THE INTERPOLATION
Legend
LAW BETWEEN ENERGIES
IS COPIED AS INPUT (I.E., NO ATTEMPT IS
Legend
MADE TO LINEARIZE THE
VARIATION WITH ENERGY). FOR EACH ENERGY AT
Legend
AT WHICH TABULATED
DATA ARE GIVEN A LINEARLY INTERPOLABLE ANGULAR
Legend
DISITRIBUTION IS CONSTRUCTED
IN THE SYSTEM IN WHICH THE TABULATED
Legend
DATA ARE GIVEN (I.E.,
CM OR LAB - NO ATTEMPT IS MADE TO CONVERT
Legend
FROM ONE SYSTEM TO
THE OTHER). A MAXIMUM OF 20000 POINTS IS ALLOWE Legend
TO REPRESENT THE
ANGULAR DISTRIBUTION AT EACH ENERGY. Legend
Legend
ELIMINATION OF
NEGATIVE VALUES Legend
------------------------------
Legend
THE RECONSTRUCTED
ANGULAR DISTRIBUTION WILL BE TESTED AND IF IT Legend
IS NEGATIVE AT ONE OR
MORE COSINES AN ERROR MESSAGE WILL BE OUTPUT Legend
AND BASED ON THE
INPUT OPTION SELECTED ONE OF THE FOLLOWING Legend
CORRECTIVE ACTIONS
WILL BE TAKEN (SEE, INPUT OPTIONS),
Legend
(1) NO
CORRECTION Legend
(2) CHANGE ALL
TABULATED VALUES TO FORCE DISTRIBUTION TO BE Legend
POSITIVE (MINIMUM
MORE THAN 1 MILLI-BARN). THE MINIMUM VALUE
Legend
MAY BE CHANGED BY
INPUT. WITH THIS OPTION THERE IS NO
Legend
RESTRICTION ON
THE AMOUNT THAT EACH VALUE IS CHANGED AND AS
Legend
SUCH THIS OPTION
SHOULD BE USED WITH CAUTION AND ONLY AS A
Legend
LAST RESORT IF NO
OTHER APPROACH CAN BE USED TO MAKE THE
Legend
DISTRIBUTION
POSITIVE. Legend
Legend
OUTPUT
Legend
------
Legend
THE OUTPUT WILL BE
THE LINEARIZED ANGULAR DISTRIBUTION. THE
Legend
TABULATED
DISTRIBUTION WILL BE NORMALIZED TO UNITY BEFORE OUTPUT. Legend
Legend
CORRECTING NEGATIVE
ANGULAR DISTRIBUTION
Legend
---------------------------------------- Legend
IF AN ANGULAR
DISTRIBUTION IS NEGATIVE AN ERROR MESSAGE WILL BE Legend
PRINTED AND THE USER
MAY DECIDE (BASED ON INPUT OPTION) TO,
Legend
(1) NOT PERFORM ANY
CORRECTIVE ACTION.
Legend
(2) FOR TABULATED
DISTRIBUTIONS - ADD THE SAME VALUE TO EACH POINT Legend
VALUE SUCH THAT
WHEN THE DISTRIBUTION IS RE-NORMALIZED THE
Legend
MINIMUM VALUE IS
0.001 (1 MILLI-BARN). THE MINIMUM VALUE CAN
Legend
BE CHANGED BY
INPUT. WARNING...EXCEPT FOR SELECTION OF THE Legend
MINIMUM VALUE (BY
INPUT) THE USER HAS NO CONTROL OVER HOW
Legend
MUCH THE
DISTRIBUTION IS CHANGED. THEREFORE THIS OPTION SHOULD Legend
BE USED WITH
CAUTION. Legend
(3) FOR LEGENDRE
COEFFICIENTS ONE OF TWO OPTIONS MAY BE SELECTED, Legend
(A) CHANGE INDIVIDUAL
COEFFICIENTS (NO ONE COEFFICIENT BY MORE
Legend
THAN 1 PER-CENT)
TO MAKE THE DISTRIBUTION POSITIVE WITH A
Legend
MINIMUM VALUE OF
0.001 (1 MILLI-BARN). THE MAXIMUM PER-CENT
Legend
CHANGE IN EACH
COEFFICIENT AND MINIMUM VALUE MAY BE CHANGED
Legend
BY INPUT. INPUT
THE PROGRAM CANNOT MAKE THE DISTRIBUTION
Legend
POSITIVE BY
CHANGING EACH COEFFICIENT BY UP TO THE MAXIMUM Legend
ALLOWABLE AMOUNT, THE ORIGINAL ANGULAR
DISTRIBUTION OR Legend
COEFFICIENTS WILL
BE OUTPUT. ONLY IN THE LATTER CASE SHOULD
Legend
ONE CONSIDER
USING OPTION (B) DESCRIBED BELOW. Legend
(B) LOGICALLY ADD THE
SAME VALUE TO EACH POINT VALUE SUCH THAT
Legend
WHEN THE
DISTRIBUTION IS RE-NORMALIZED THE MINIMUM VALUE IS Legend
0.001 (1
MILLI-BARN). THIS IS EQUIVALENT AT INCREASING P0 Legend
BY A CERTAIN
AMOUNT AND RE-NORMALIZATION IS EQUIVALENT TO THEN Legend
DIVIDING EACH
COEFFICIENT BY A CERTAIN AMOUNT. THEREFORE, Legend
WHAT IS
PHYSICALLY DONE BY THE PROGRAM IS TO DIVIDE EACH Legend
COEFFICIENT BY
THE SAME AMOUNT. WARNING..EXCEPT FOR SELECTION
Legend
OF THE MINIMUM
VALUE (BY INPUT) THE USER HAS NO CONTROL OVER
Legend
HOW MUCH THE
DISTRIBUTION IS CHANGED. THEREFORE THIS OPTION Legend
SHOULD BE USED
WITH CAUTION. Legend
Legend
WARNING MESSAGES FROM
PROGRAM
Legend
----------------------------- Legend
THE WARNING MESSAGES
PRINTED BY THIS PROGRAM SHOULD ONLY BE
Legend
CONSIDERED TO BE
EXACTLY THAT..WARNINGS..NOT AN ABSOLUTE JUDGEMENT Legend
BY THIS PROGRAM THAT
THERE IS SOMETHING WRONG WITH THE DATA. WHEN
Legend
WARNING MESSAGES ARE
PRINTED EXAMINE THE DATA AND EITHER TAKE NO
Legend
ACTION (IF YOU FEEL
THAT THE DATA IS O.K.) OR CORRECT THE DATA
Legend
(IF YOU FEEL THAT THE
DATA IS INCORRECT AND YOU CAN CORRECT IT).
Legend
Legend
VALIDITY OF MODIFIED
DATA
Legend
------------------------- Legend
BEFORE BELIEVING AND
USING DATA WHICH HAS BEEN MODIFIED (EITHER
Legend
TABULATED ANGULAR
DISTRIBUTIONS OR LEGENDRE COEFFICIENTS) THE USER Legend
SHOULD INSURE THAT
THE MODIFIED DATA IS PHYSICALLY MORE ACCEPTABLE Legend
THAN THE ORIGINAL
DATA. IN ORDER TO DO THIS ONE OR MORE OF THE Legend
FOLLOWING METHODS
SHOULD BE USED, Legend
Legend
(1) USE THE ENERGY
VARIATION TESTS BUILT-IN TO THIS PROGRAM AND
Legend
EVALPLOT TO PLOT
THE ENERGY DEPENDENCE OF THE LEGENDRE
Legend
COEFFICIENTS IN
ORDER TO IDENTIFY AND CORRECT (BY HAND...NOT
Legend
BY THIS PROGRAM)
ANY COEFFICIENTS WHICH HAVE UNREALISTIC
Legend
ENERGY AND L
ORDER VARIATIONS. THIS SHOULD ALWAYS BE DONE Legend
FIRST TO
ELIMINATE MAJOR PROBLEMS BEFORE USING THIS PROGRAM Legend
TO AUTOMATICALLY
MAKE MINOR CORRECTIONS.
Legend
(1) OUTPUT AND PLOT
THE UNCORRECTED AND CORRECTED ANGULAR
Legend
DISTRIBUTIONS.
COMPARE THE PLOTS TO INSURE THAT THE CORRECTED
Legend
DATA DOES NOT
SERIOUSLY CHANGE THE ENERGY DEPENDENCE OF THE Legend
ANGULAR
DISTRIBUTION. Legend
(2) IF PLOTTING
CAPABILITY IS NOT AVAIALABLE, USE THE PRINTED OUT Legend
OF THIS PROGRAM
TO DETERMINE HOW MUCH THE TABULATED ANGULAR
Legend
DISTRIBUTION OR
LEGENDRE COEFFICIENTS HAVE BEEN MODIFIED.
Legend
GENERALLY IF ONE
COEFFICIENT HAS BEEN ONLY SLIGHTLY MODIFIED
Legend
THE DISTRIBUTION
WILL BE ACCEPTABLE. HOWEVER IF MANY
Legend
COEFFICIENTS HAVE
BEEN MODIFIED THE RESULT WILL NOT BE
Legend
RELIABLE.
Legend
Legend
SEEING ANGULAR
DISTRIBUTIONS AND LEGENDRE COEFFICIENTS Legend
------------------------------------------------------ Legend
PROGRAM EVALPLOT CAN
BE USED TO PLOT ANGULAR DISTRIBUTION AND
Legend
LEGENDRE COEFFICIENTS
- WHEN IT COMES TO CHECKING THIS TYPE OF
Legend
DATA THERE IS NO
SUBSTITUTE FOR PLOTS OF THE DATA TO MAKE THE Legend
JOB EASY AND
STRAIGHTFORWARD. Legend
Legend
FOR LEGENDRE
COEFFICIENTS EVALPLOT CAN BE USED TO SEE THE ENERGY Legend
DEPENDENCE OF EACH
COEFFICIENT - THIS IS AN EXTREMELY EASY AND
Legend
USEFUL WAY TO CHECK
FOR ERRORS IN THE BASIC DATA.
Legend
Legend
FOR ANGULAR
DISTRIBUTION EVALPLOT CAN BE USED TO PLOT THEM AT Legend
EACH ENERGY THAT THEY
ARE TABULATED - THIS IS ALSO AN EASY AND
Legend
USEFUL WAY TO CHECK
FOR ERRORS.
Legend
Legend
I/O UNIT
DEFINITIONS Legend
-------------------- Legend
UNIT DESCRIPTION Legend
---- ----------- Legend
2 INPUT CARDS Legend
3 OUTPUT REPORT Legend
10 ORIGINAL DATA IN ENDF/B FORMAT Legend
11 FINAL DATA IN ENDF/B FORMAT Legend
Legend
OPTIONAL STANDARD
FILE NAMES (SEE SUBROUTINE FILIO1 AND FILIO2) Legend
--------------------------------------------------------------- Legend
UNIT FILE NAME Legend
---- ---------- Legend
2
LEGEND.INP Legend
3 LEGEND.LST Legend
10 ENDFB.IN Legend
11 ENDFB.OUT Legend
Legend
INPUT CARD
Legend
---------- Legend
CARD COLS. FORMAT
DESCRIPTION Legend
---- ----- ------ ----------- Legend
1 1-11
E11.4 FRACTIONAL THINNING CRITERIA Legend
12-22 I11
MAXIMUM NUMBER OF POINTS IN ANGULAR DISTRIBUTION Legend
RECONSTRUCTED FROM LEGENDRE COEFFICIENTS (PRESENT Legend
LIMITS
ARE 11 TO 20000 POINTS)
Legend
*THIS
OPTION CAN BE USED TO RUN QUICK, BUT NOT
Legend
NECESSARILY SO ACCURATE CALCULATIONS - TO ROUGHLY Legend
SEE
WHAT THE ANGULAR DISTRIBUTIONS LOOK LIKE.
Legend
*IT IS
RECOMMENDED THAT YOU USE 0 AS INPUT - IN
Legend
WHICH
CASE THE PROGRAM WILL USE THE MAXIMUM
Legend
ALLOWABLE NUMBER OF POINTS = 20000. Legend
23-33 I11
TABULATED ANGULAR DISTRIBUTION TREATMENT Legend
= 0 -
COPY TABLES
Legend
= 1 -
LINEARIZE TABLES (OUTPUT TABLES)
Legend
= 2 -
LINEARIZE AND THIN TABLES (OUTPUT TABLES)
Legend
34-44 I11
LEGENDRE COEFFICIENT TREATMENT Legend
= 0 -
COPY LEGENDRE COEFFICIENTS
Legend
= 1 - RECONSTRUCT TABULATED
ANGULAR DISTRIBUTION. Legend
(OUTPUT TABLES). Legend
= 2 -
RECONSTRUCT TABULATED ANGULAR DISTRIBUTION.
Legend
(OUTPUT LEGENDRE
COEFFICIENTS). Legend
45-55 I11
NEGATIVE ANGULAR DISTRIBUTION TREATMENT. Legend
= 0 -
NO CORRECTION
Legend
= 1 -
TABULATE DATA - NO CORRECTION.
Legend
-
LEGENDRE DATA - CHANGE COEFFICIENTS
Legend
(NONE BY MORE THAN 1.0 PER-CENT - CAN BE Legend
CHANGED BY INPUT). Legend
= 2 -
FORCE DISTRIBUTIONS TO BE POSITIVE
Legend
(TABULATED OR LEGENDRE DATA). Legend
56-66 I11
LEGENDRE COEFFICIENT VARIATION TEST FLAG. Legend
= 0 -
TEST TESTS.
Legend
= 1 -
PERFORM TESTS,
Legend
(A) LEGENDRE ORDER INCREASES WITH ENERGY. Legend
(C) MONOTONIC VARIATION OF COEFFICIENTS Legend
AS A FUNCTION OF ENERGY. Legend
(C) COEFFICIENTS DECREASE AS A FUNCTION OF Legend
LEGENDRE ORDER. Legend
2 1-60
A60 ENDF/B INPUT DATA
FILENAME
Legend
(STANDARD OPTION = ENDFB.IN) Legend
3 1-60
A60 ENDF/B OUTPUT DATA
FILENAME
Legend
(STANDARD OPTION = ENDFB.OUT) Legend
4-N 1- 6
I6 LOWER MAT LIMIT
Legend
7- 8
I2 LOWER MF LIMIT Legend
9-11 I3
LOWER MT LIMIT Legend
12-17 I6
UPPER MAT LIMIT Legend
18-19 I2
UPPER MF LIMIT Legend
20-22 I3
UPPER MT LIMIT Legend
23-33 E11.4
LOWER ENERGY LIMIT Legend
34-44 E11.4
UPPER ENERGY LIMIT Legend
45-55 E11.4
MINIMUM ALLOWABLE VALUE OF ANGULAR DISTRIBUTION Legend
56-66 E11.4
ALLOWABLE FRACTION (NOT PER-CENT) CHANGE IN ANY Legend
ONE
LEGENDRE COEFFICIENT TO MAKE THE ANGULAR
Legend
DISTRIBUTION POSITIVE (AND AT LEAST EQUAL TO THE Legend
INPUT
MINIMUM ALLOWABLE VALUE).
Legend
Legend
*UP TO 100 MAT/MT/E
RANGES MAY BE INPUT, EACH SPECIFYING AN
Legend
ALLOWABLE MINIMUM
SIGMA AND MAXIMUM CHANGE IN COEFFICIENTS.
Legend
*INPUT IS TERMINATED
BY A BLANK CARD. Legend
*ALL MAY/MT/E RANGES
NOT SPECIFIED BY INPUT WILL BE TREATED BY
Legend
ALLOWING A MINIMUM
SIGMA OF 0.001 (1 MILLI-BARN) AND A CHANGE
Legend
IN EACH COEFFICIENT
BY UP TO 0.01 (1 PER-CENT). Legend
*THESE MAT/MT/E
RANGES ARE NOT USED TO CORRECT ALL ANGULAR Legend
DISTRIBUTIONS WHERE
SIGMA IS LESS THAN THE MINIMUM. THEY ARE
Legend
ONLY USED TO CORRECT
DISTRIBUTION THAT ARE NEGATIVE AND TO
Legend
INSURE THAT THE
CROSS SECTION AT THE COSINES WHERE THE ANGULAR Legend
DISTRIBUTION ARE
INITIALLY NEGATIVE ARE CORRECTED TO BE POSITIVE Legend
AND AT LEAST AS
LARGE AS THE MINIMUM ALLOWABLE SIGMA (SPECIFIED Legend
BY INPUT). Legend
Legend
EXAMPLE INPUT NO.
1 Legend
-------------------
Legend
PROCESS BOTH LEGENDRE
COEFFICIENTS AND TABULATED DATA TO OBTAIN
Legend
ANGULAR DISTRIBUTION
WHICH ARE ACCURATE TO WITHIN 0.1 PER-CENT
Legend
AND OUTPUT UNCORRECTED
TABULATED ANGULAR DISTRIBUTION USING
Legend
A MAXIMUM OF 501
POINTS IN EACH TABULATED ANGULAR DISTRIBUTION. Legend
SINCE LEGENDRE
COEFFICIENTS WILL NOT BE CORRECTED THE INPUT NEED Legend
NOT SPECIFY MAT/MT/E
RANGES.
Legend
Legend
READ
/ENDFB6/K300/LEAD.IN AND WRITE /ENDFB6/K300/LEAD.OUT Legend
Legend
THE FOLLOWING 4 INPUT
LINES ARE REQUIRED,
Legend
Legend
1.00000- 3 501 2 1 0
Legend
/ENDFB6/K300/LEAD.IN
Legend
/ENDFB6/K300/LEAD.OUT Legend
(BLANK CARD
TERMINATED INPUT)
Legend
Legend
EXAMPLE INPUT NO.
2 Legend
------------------- Legend
PROCESS BOTH LEGENDRE
COEFFICIENTS AND TABULATED DATA TO OBTAIN
Legend
ANGULAR DISTRIBUTION
WHICH ARE ACCURATE TO WITHIN 0.1 PER-CENT
Legend
AND OUTPUT CORRECTED
TABULATED ANGULAR DISTRIBUTION (ONLY THOSE
Legend
RE-CONSTRUCTED FROM
LEGENDRE COEFFICIENTS WILL BE CORRECTED).
Legend
FOR ALL MAT/MT/E
CORRECT NEGATIVE ANGULAR DISTRIBUTION TO A VALUE Legend
OF 0.01 (10
MILLI-BARNS) AND ALLOW LEGENDRE COEFFICIENTS TO BE Legend
CHANGED BY UP TO 0.02
(2 PER-CENT).
Legend
Legend
USE THE DEFAULT
FILENAMES ENDFB.IN AND ENDFB.OUT (THIS CAN BE Legend
DONE BY LEAVING THE
SECOND AND THIRD INPUT LINES BLANK).
Legend
Legend
THE FOLLOWING 5 INPUT
LINES ARE REQUIRED,
Legend
Legend
1.00000- 3 501 2 1 1 Legend
Legend
Legend
1 1 1
999999999 0.00000+ 0 3.00000+ 7 1.00000- 2 2.00000- 2 Legend
(BLANK CARD
TERMINATED INPUT) Legend
Legend
EXAMPLE INPUT NO.
3 Legend
------------------- Legend
PROCESS BOTH LEGENDRE
COEFFICIENTS AND TABULATED DATA TO OBTAIN
Legend
ANGULAR DISTRIBUTION
WHICH ARE ACCURATE TO WITHIN 0.1 PER-CENT
Legend
AND OUTPUT CORRECTED
LEGENDRE COEFFICIENTS AND UNCORRECTED
Legend
TABULATED ANGULAR
DISTRIBUTIONS. FOR MAT=1800, MT=2 CORRECT
Legend
NEGATIVE ANGULAR
DISTRIBUTIONS TO INSURE THE MINIMUM IS 0.01 Legend
(10 MILLI-BARNS)
ALLOWING EACH LEGENDRE COEFFICIENT TO CHANGE BY Legend
UP TO 0.02 (2
PER-CENT). ALL OTHER MAT/MT/E WILL BE CORRECTED Legend
TO A MINIMUM OF 0.001
(1 MILLI-BARN) ALLOWING A 0.01 (1 PER-CENT)
Legend
CHANGE (BUILT-IN
OPTION). Legend
Legend
READ
/ENDFB6/K300/LEAD.IN AND WRITE /ENDFB6/K300/LEAD.OUT Legend
Legend
THE FOLLOWING 5 INPUT
LINES ARE REQUIRED,
Legend
Legend
1.00000- 3 501 2 2 1 Legend
/ENDFB6/K300/LEAD.IN
Legend
/ENDFB6/K300/LEAD.OUT Legend
1800 4 2
1800 4 2 0.00000+ 0 3.00000+ 7
1.00000- 2 2.00000- 2 Legend
(BLANK CARD
TERMINATED INPUT) Legend
Legend
EXAMPLE INPUT NO.
4 Legend
------------------- Legend
TO COPY TABULATED
ANGULAR DISTRIBUTION AND CONVERT LEGENDRE Legend
COEFFICIENTS TO
UNCORRECTED TABULAR DISTRIBUTIONS. Legend
Legend
USE THE DEFAULT
FILENAMES ENDFB.IN AND ENDFB.OUT (THIS CAN BE Legend
DONE BY LEAVING THE
SECOND AND THIRD INPUT LINES BLANK).
Legend
Legend
THE FOLLOWING 4 INPUT
LINES ARE REQUIRED, Legend
Legend
1.00000- 3 501 0 1 0 Legend
Legend
Legend
(BLANK CARD
TERMINATED INPUT) Legend
Legend
=======================================================================
Legend